Product details

GENERAL  Tunnel lighting luminaire, part of BUCK smart tunnel illumination system. Appropriate for various tunnel types and other harsh environments with high ambient temperatures Ta ≤ 55℃. It’s longevity, energy efficiency and overall reliable performance ensure low usage costs. 

OPTICS  A wide range of PMMA lenses assures optimal lighting solution for any tunnel situation. Required lighting intensities and uniformities are ensured while high energy efficiency is achieved. 
Basically, two types of light distributions are used for tunnel lighting: 
SYM – symmetric light distribution is used for interior and entrance zone luminaires; 
ASY – asymmetric light distribution is used for entrance and exit zone luminaires as counterbeam or probeam application. 
Optics protector is made of 5 mm tempered glass.  

HOUSING  Made of stainless steel 1.4571 / AISI 316 Ti (electrochemically polished and passivated for highest resistance to corrosion) and extruded aluminium alloy heatsink with conversion protection. The heatsinks are isolated from stainless steel housing, so there is no possibility of galvanic corrosion. 

LIGHTING MANAGEMENT  Smart LED lighting solutions for tunnels and subways include fully integrated control systems to monitor and manage various factors such as levels of light outside and inside the tunnel, speed and density of traffic, various tunnel zones, motion, presence, speed detection… Buck provides various solutions for luminaires control such as analog current loop 4-20 mA interface (CLi), discrete time coded 230 V step dim interface (SDi), digital bidirectional RS-485 interface (RSi). 

FEATURES  Luminaire system consists of lighting units (VISION) and drivers for powering of LED light source. Drivers can be dislocated in the electro-niche, or in the junction boxes (JB) with through-wiring functionality, or integrated inside luminaire (IN). Performance and safety in different types of tunnels are achieved with a properly chosen optics from a wide range of light distributions. Easy mounting with fixed or adjustable brackets. Longevity assured by advanced protection against corrosion, impact and overheating.

Technical data

street lighting
CE marking
mounting on normally flammable surfaces
ingress protection
voltage
frequency
lamp type
* Please select the row to enable viewing and downloading of additional material.
Order code Description A/B/H[mm] WEIGHT [kg] FLUX [lm]* IP Total Power [W] CCT [K] CRI Led Service Life
6426103XY VISION HT IN 3 SYM 509x296x60 9.00 12035 IP66 88.0 4000 >70 100000h L90B10 / SDCM3
6426206XY VISION HT 6 ASY 690x296x60 9.50 23210 IP66 176.0 4000 >70 100000h L90B10 / SDCM3
6426208XY VISION HT 8 ASY 690x591x60 16.00 33095 IP66 254.0 4000 >70 100000h L90B10 / SDCM3
6426212XY VISION HT 12 ASY 690x591x60 16.50 43952 IP66 335.0 4000 >70 100000h L90B10 / SDCM3
* Luminaire luminous flux and connected electrical load - initial tolerance of ±10 % (at ambient temperature of 25° C).
** Replace XY with the color code when ordering ( e.g. 11 white, 21 grey, 31 black).

Lighting solutions you need

Cookies allow page content to be adapted according to the needs of users, thus providing improved functionality and an improved user experience. Cookies can also be used to analyze the use of websites, as well as for advertising purposes. By clicking on "I accept" you agree to the use of cookies. You can change your cookies settings at any time.

Notification